FLIR DM93-2 vs Fluke 87V | Industrial Multimeter Comparison
Answer-First Summary
The FLIR DM93-2 and Fluke 87V are two well-known industrial multimeters built for demanding electrical work. Both provide True RMS accuracy and advanced filtering for noisy VFD (Variable Frequency Drive) applications. The FLIR DM93-2 adds modern features such as Bluetooth connectivity (METERLiNK®), bright LED worklights, and extended thermocouple temperature support. The Fluke 87V remains a solid, field-tested option with strong safety ratings, though it lacks the newer usability features found in the FLIR.
M-Testco certifies both models with NIST-traceable calibration to keep equipment accurate and compliant.
Side-by-Side Specification Table
Feature / Capability | FLIR DM93-2 (Certified by M-Testco) | Fluke 87V (Certified by M-Testco) |
---|---|---|
VFD Filtering | Yes – built-in VFD filter + LoZ mode | Yes – selectable low-pass filter |
True RMS | Standard across AC/DC voltage & current | Standard across AC/DC voltage & current |
Temperature | Type-K thermocouple input (–200 °C to 1200 °C) | Built-in thermometer (industrial range) |
Accuracy | ±0.05% DC voltage; ±0.1% AC voltage typical | ±0.05% DC voltage; ±0.1% AC voltage typical |
Frequency Bandwidth | Up to 100 kHz with filtering | Up to 20 kHz with filtering |
Safety Ratings | CAT IV 600 V / CAT III 1000 V | CAT IV 600 V / CAT III 1000 V |
Ruggedness | IP54, drop tested to 3 m | Durable build, widely field-used |
Display / UI | Bright LED worklights, dual display, bar graph | Backlit digital display, analog bar graph |
Connectivity | METERLiNK® Bluetooth integration | None |
Special Features | LoZ mode, Peak hold, LED worklights | Peak capture, data logging |
❓ Q&A Section
Q: Which multimeter handles noisy VFD environments better?
A: Both models include advanced filtering for VFDs. The FLIR DM93-2 adds a LoZ mode, giving it an extra layer of safety and flexibility.
Q: Which offers stronger temperature measurement?
A: The FLIR DM93-2 supports a wide thermocouple range (–200 °C to 1200 °C), while the Fluke 87V has a built-in thermometer but with a narrower range.
Q: Which is more rugged?
A: Both are built for industrial use, with CAT IV/CAT III safety ratings. The Fluke 87V has a long record in the field. The FLIR DM93-2 matches industrial durability (IP54, 3 m drop test) while also providing modern usability features.
Q: How do the displays compare?
A: The FLIR DM93-2 includes a bright backlit display, LED worklights, and dual digital readout. The Fluke 87V offers a classic backlit display with analog bar graph and peak capture, but no lighting or connectivity features.
Q: Can M-Testco service both models?
A: Yes. M-Testco provides NIST-traceable certification and calibration for both the FLIR DM93-2 and the Fluke 87V.
Best Choice by Application
-
Feature-Rich Modern Workflows → FLIR DM93-2 (Certified by M-Testco)
-
Basic Industrial Durability → Fluke 87V (Certified by M-Testco)
M-Testco Advantage
M-Testco ensures industrial professionals have accurate, compliant meters:
-
FLIR DM93-2 → Certified with NIST traceability
-
Fluke 87V → Certified with NIST traceability
-
Fast turnaround available at Houston
Call to Action
✅ Certify your FLIR DM93-2 or Fluke 87V with M-Testco today — ensuring reliable, NIST-traceable accuracy for every job.